Abstract
OBJECTIVES: The present prospective randomized trial compared surgical tracheostomy (ST) and percutaneous dilatational tracheostomy (PDT) in intensive care unit (ICU) patients in terms of outcomes and complications. METHODS: Between January 2003 and December 2005 tracheostomies were performed on critically ill ICU patients in Medical Faculty Hospital in Prague, with a random allocation of 105 patients for ST and 100 for PDT. RESULTS: The 2 groups did not differ significantly in terms of basic demographic characteristics or length of endotracheal intubation prior to the procedure. Following the procedures, the 2 groups did not differ significantly in terms of the time required for decannulation, decannulated patients or mortalities. Post-mortem examination showed that both groups were similar in terms of placement of the tracheostomy tube. Surgical tracheostomy was found to take longer time to perform than PDT (p<0.001). In terms of early postoperative complications, PDT was associated with a higher rate of postoperative bleeding compared to ST (p=0.0302). CONCLUSIONS: Percutaneous dilatational tracheostomy is a simpler and faster technique to perform, but is associated with a higher occurrence of early complications, particularly postoperative bleeding.
Article Type
Research Article
First Page
1529
Last Page
1533
Recommended Citation
Lukas, Jindrich; Duskova, Jaroslava; Lukas, David; Paska, Jan; Stritesky, Martin; and Haas, Tomas
(2007)
"Standard surgical versus percutaneous dilatational tracheostomy in intensive care patients.,"
Saudi Medical Journal: Vol. 28:
Iss.
10, Article 12.
DOI: https://doi.org/10.15537/1658-3175.4090